Mercury emission characteristics from coal-fired power plants

Liguo Yang,Yufeng Duan,Xianghua Yang,Yiman Jiang,Yunjun Wang,Changsui Zhao
DOI: https://doi.org/10.3321/j.issn:1001-0505.2007.05.016
2007-01-01
Abstract:To evaluate the mercury emissions, and to comprehend and compare the speciation characteristics of mercury in different power plants, six representative coal-fired power plants were selected, of which there were five pulverized coal boilers and one circulating fluidized bed boiler, whose capacities ranged from 50 MW to 600 MW with different flue gas cleaning up devices such as electrostatic precipitator (ESP), fabric filter (FF) and flue gas desulfurization (FGD). Samples of feeding coal, bottom ash, fly ash, desulfurization sorbent and flue gas were taken at the inlet and outlet of pollution control devices from the six different coal-fired power plants. The results of mercury emission and mercury balance show that the mercury speciation distribution changes greatly depending on coal types, combustion boilers and different air pollution control devices (APCD). The fly ash exerts different influences on mercury adsorption, and the chlorine content in flue gas can convert more oxidized mercury. It is shown that circulating fluidized bed combustion (CFBC) can decrease the total gaseous mercury emission, however the mechanism needs to be further investigated.
What problem does this paper attempt to address?