An Experimental Study of Mercury Emissions from a 600 MW Pulverized Coal-fired Boiler

周劲松,王光凯,骆仲泱,岑可法
DOI: https://doi.org/10.3969/j.issn.1001-2060.2006.06.005
2006-01-01
Abstract:To evaluate the emission level of mercury from large-sized pulverized coal-fired boilers, the mercury content was determined from samples of coal, combustion product flue gas, fly ash and bottom slag taken from a 600 MW coal-fired utility boiler. The boiler has been operating at full load and also about 70% load under peak-shaving conditions. Through a study of the distribution of mercury content in combustion products under different operating conditions and of the change of mercury configuration before and after the ESP (Electro-static Precipitators) etc., the mercury emission characteristics of a 600 MW pulverized coal-fired boiler have been obtained. Through the experiments one can discover that the mercury in the 600 MW boiler has been emitted mainly in the form of gas with the total amount of gaseous mercury in the flue gas varying from 4.99 to 14.79 μg/Nm3. Moreover, the percentage content of zero-valence mercury is relatively high and there is little change in gaseous mercury configuration before and after the ESP. The removal rate of particle mercury amounts to over 90%.
What problem does this paper attempt to address?