ESTIMATION OF MERCURY EMISSION FROM COAL- FIRED BOILERS IN TYPICAL POWER PLANTS OF CHINA

Chang-xing HU,Jin-song ZHOU,Sheng HE,Zhong-yang LUO,Ke-fa CEN
DOI: https://doi.org/10.3969/j.issn.1002-3364.2010.03.001
2010-01-01
Abstract:Centred on the estimation of mercury emission from coal-fired boilers in power plants,a model for estimating the mercury emission from typical coal-fired boilers has been established.Based on practically measured data of mercury emission from coal-fired boilers in typical power plants,the mecury emission affecting coefficient Fij in each part of typical coal-fired boiler system has been determined,at the same time,the annual mercury emission from coal-fired boilers in typical power plant being estimated.The total mercury emission from typical coal-fired boilers of of 100 MW unit is about 40~50 kg/year in China.In the event of only electrostatic precipitator(EP) being allocated in tail section of the boiler,the gaseous mercury emission ratio reaches up about 80%;in the case of EP and wet flue gas desulphurization(WFGD) system being simultaneously allocated,the gaseous mercury emission ratio decreased to 30% of the total mercury emission;if EP,WFGD,and selective catalytic reduction(SCR) being used together,the gaseous mercury emission may decrease below 15% of the total mercury emission.
What problem does this paper attempt to address?