Industrial Test on Coal Re-Burning at a 600 MW Utility Boiler and NOx Reduction

Penghua Qiu,Shaohua Wu,Shaozeng Sun,Hui Liu,Longbin Yang,Guozhong Wang
DOI: https://doi.org/10.1007/s11814-007-0026-6
IF: 2.7
2007-01-01
Korean Journal of Chemical Engineering
Abstract:This research conducts a series of industrial tests on coal reburning of a 600 MW pulverized coal boiler firing lignite, which is one part of a coal reburning demonstration project. When running steadily under 600 MW load, the boiler has an average NO x emission of 274 mg/m 3 (O 2 content in flue gas is converted to 6%), the NO x emission is reduced by 65.36%. In the meanwhile, loss of ignition (LOI) under coal reburning rarely increases. Three operation conditions — traditional air feeding, air staging and coal reburning — are realized, respectively, during the industrial tests, and the results indicate that coal reburning has the lowest NO x emission, while the traditional air feeding has the highest NO x emission. Under the test conditions, the higher the proportion of the reburning coal, the higher the NO x control can reach.
What problem does this paper attempt to address?