Study on Hydrolytic- Acidification (HA) during the Treatment of Wastewater in Recycled Fibers base Mills

MA Yong-wen,WU Jiao,WAN Jin-quan,WANG Pei,WANG Yan
DOI: https://doi.org/10.3969/j.issn.0254-508X.2006.10.007
2006-01-01
Abstract:Several experiments were carried out in lab to study the factors affecting hydrolytic-acidification during the treatment of wastewater in recycled fibers base mills. Batch tests suggested that it was suitable for acidification at pH 6-7, COD removal rate reached 50.6% at pH 7, the effluent COD obviously increased at pH 4. COD removal rate increased 10% with every 10°C increased at 20-40°C. The effect of HA became worse at 50°C. Continuous-flow tests indicated that there was a increasing tendency for COD removal rate with longer HRT, and VFA concentration increased firstly and then decreased with the HRT continuously prolonged. HRT at 8 hours can be defined as the dividing point of two HA phases.
What problem does this paper attempt to address?