Experimental investigation on pulse tube cooler driven by novel thermoacoustic engine

Da-ming SUN,Li-min QIU,Yong-xiang TAN,Wei-lin YAN,Ping CHEN,Guo-bang CHEN
DOI: https://doi.org/10.3785/j.issn.1008-973X.2005.03.013
2005-01-01
Abstract:In order to completely eliminate moving parts, simplify configuration and obtain high reliability in cryogenic system, experimental investigation on a thermoacoustic system composed of a pulse tube cooler (PTC) and a self-made thermoacoustic engine was carried out. With thorough experimental analysis of the thermoacoustic engine, the preferable filling pressure and connecting location of PTC were determined. Then a single-stage orifice PTC was connected to the engine. The performance of the PTC was optimized by adjusting its orifice. The results show that charged with helium at 2.0 MPa, the engine operating with no load had the maximum pressure ratio of 1.19. The single stage orifice PTC driven by the engine reached 119 K, and the PTC driven by the proposed thermoacoustic systems can be applied for natural gas liquefaction.
What problem does this paper attempt to address?