Stress analysis and breakage evaluation of zirconia ceramic sleeves for optical connector

Wenjie Si,Chunguang Li,Yin Wu,Lianjun Sheng,Bin Gao,Hongjuan Wang
DOI: https://doi.org/10.3321/j.issn:1002-185x.2005.z1.078
2005-01-01
Rare Metal Materials and Engineering
Abstract:Finite Element Analysis calculated the working stress of zirconia optical sleeves under different conditions in this paper. Under normal conditions, the working stress is below 100 MPa, which is much lower than the strength of the zirconia sleeve, which is at the range of 450 MPa to 1 150 MPa. When the local concentrated stress exists, the local stress at the end face of sleeve will be higher than 2000 MPa, the breakage of the sleeve occurs. After the proof test of the zirconia sleeves by the method of preloading of a load of 100 N to 150 N or insertion of a larger ferrule of 2.520 mm to 2.530 mm (OD), the breakage probability of the sleeves in practice use will be decreased significantly.
What problem does this paper attempt to address?