Stress Analysis Of Zirconia Abutments For Dental Implants By Finite Element Method

Jiang Songji,Wu Yin,Si Wenjie
2015-01-01
Rare Metal Materials and Engineering
Abstract:To analyze the Straumann 4.1 mm dental implant and abutment system, inclined loaded condition of dental implants was simulated by finite element analysis. Three different models of titanium abutment, zirconia abutment and zirconia abutment with Ti-base were calculated. 300 N inclined force loading by 30 degrees angle was simulated in PEA software. The peak value of equivalent stress of all the systems is located at the implant-abutment surface. The peak value of maximum principal stress of zirconia abutment without Ti-base is very close to the fracture strength of zirconia, while that of zirconia abutment with Ti-base is much lower.
What problem does this paper attempt to address?