The Marginal Fit of Ni-Cr Alloy Crown Cemented on Implant Abutments with Chamfer Margin

夏海斌,王贻宁,程祥荣,施斌
DOI: https://doi.org/10.3969/j.issn.1671-8852.2004.01.014
2004-01-01
Abstract:Objective: To observe the marginal fit of Ni-Cr alloy crown cemented on implant abutments with chamfer margin and shoulder margin. Methods: 24 plexiglass dies of implant abutments with chamfer margin and shoulder margin were finely processed through the precision machine tool. Zinc oxide-eugenol (ZOE) and zinc phosphate (ZP) were respectively used to cement the Ni-Cr alloy crowns on their dies of abutments, and the cross-sectioned technique was used to measure the marginal opening of cemented crowns. Results: The difference of the marginal opening of chamfer margin (52.67 μm) and shoulder margin (57.88 μm) crowns had no statistical significance for ZOE, while the marginal opening of both were significantly smaller than those for ZP. When ZP was used, the marginal opening of shoulder margin group (159.08 μm) was statistically higher than that of chamfer margin group (122.71 μm). Conclusion: The marginal discrepancy of metal crowns with ZOE is significantly smaller than that of crowns with ZP. The different shape of abutment margin has little influence on the marginal fit of crowns for ZOE and had important influence for ZP, and the chamfer margin is superior to shoulder margin for the marginal sealing of metal crowns.
What problem does this paper attempt to address?