Application of Thermoacoustic Effect to Refrigeration

T Jin,GB Chen,BR Wang,SY Zhang
DOI: https://doi.org/10.1063/1.1518571
2003-01-01
Abstract:Thermoacoustic effect, as a subprocess of the photoacoustic effect, can also convert heat to acoustic wave by a thermoacoustic prime mover, and can also pump heat by acoustic wave in a thermoacoustic refrigerator. The present study focuses on a thermoacoustically driven pulse tube refrigerator, utilizing sound from a thermoacoustic prime mover to drive a pulse tube refrigerator. Experiments emphasize on the characteristics of both the thermoacoustic prime mover and the combined refrigeration system, including resonant frequency, onset temperature, pressure amplitude, and refrigeration temperature, etc. A cryogenic temperature lower than 120 K has been achieved from the present system. Much effort is also devoted to the influence of some working gases, such as helium–argon mixture, on the performance of the system.
What problem does this paper attempt to address?