The Development and Evaluation of Solid-State Detector Arrays for High Energy X-Ray Imaging

YL Li,YJ Li,SF Wang,SW Li,HL He
DOI: https://doi.org/10.1109/nssmic.2003.1351949
2003-01-01
Abstract:Several detector modules which consist of linear CdWO/sub 4/ crystal arrays optically coupled to photodiode arrays were developed for a high energy X-ray NDT system. An electron linear accelerator (LINAC) which produces pulsive X rays with maximum energy of 9 MeV is used for X ray source. 16 channels were assembled in each module, with crystal size of 0.8 mm /spl times/ 5 mm /spl times/ 30 mm and pitch size of 1.3 mm. Lead spacers were placed between crystals to reduce the cross-talk. Based on M-C simulation, the detection efficiency of the detector can reach 70%, energy deposit rate 30%, while crosstalk can be reduced to 5%. After fabrication, we tested their performances under the radiation sources of /sup 60/Co, 6 MeV LINAC and 9 MeV LINAC. The results show that the arrays satisfy the meet of the NDT system.
What problem does this paper attempt to address?