Improvement on rich gas compression system: direct water-cooling method

曹新波,段占庭
DOI: https://doi.org/10.3321/j.issn:0253-4320.2002.10.012
2002-01-01
Abstract:A novel process, direct water-cooling method, is introduced. It can greatly enhance the inlet pressure of rich gas compressor, reduce power consumption, increase production capacity, and improve separation effects. For an industrial unit of 1.5 Mt/y as a basic standard, simulation results indicate that the inlet pressure of rich gas compressor is increases by 50 kPa and compressor's power consumption is decreased by 11.8%, compared with the old process.