Experimental and Numerical Mode Studies on Cold End Metal Temperature of 600MW Rotating Air Heater

潘维,池作和,李戈,孙荣华,周昊,蒋啸,岑可法
DOI: https://doi.org/10.3785/j.issn.1008-973x.2002.05.006
2002-01-01
Abstract:In practical operation, the cold end metal of a Rotating Air Heater is easily eroded. This may affect heat transfer and lower the economic operation. A steam preheater is normally used to increase the average temperature of the cold end. Because the heat transfer surfaces are rotating all the time, the measurement is very difficult. Here a smart method to measure the temperature was designed and the temperature distributions under different experimental conditions were obtained. A suitable numerical simulation model put forward in a reference article was selected and programmed in Fortran Language. The calculation results compared well with the measured results.
What problem does this paper attempt to address?