THE RESEARCH OF THE CAUSE OF VELOCITY IMBALANCE IN A TANGENTIALLY-FIRED FURNACE

刘泰生,姚本荣,许晋源
DOI: https://doi.org/10.3321/j.issn:0258-8013.2002.01.010
2002-01-01
Abstract:In an isothermal model with a 600 MW tangentially-fired boiler as its prototype, the velocity field was carefully measured with a hot-wire anemometer. The principles of gas flow in the plate zone and dissipation of the swirl along the vertical direction in the furnace were acquired. The residual swirl of gas flow which flows into the panel zone and the function of the plates which can't effectively cut and distribute swirling gas lead to the velocity deviation in the horizontal gas-pass. The author presented three measures to decrease the velocity deviation in the horizontal gas-pas from the results of the test: decreasing the residual swirl of gas flow which flows into the panel zone; improving the structure of the plates to cut and distribute swirling gas effectively; decreasing the gas velocity in the bottom right corner of the horizontal gas-pass.
What problem does this paper attempt to address?