RESEARCH ON AERODYNAMIC FIELD EXPERIMENTS AND NUMERICAL SIMULATION FOR THE SWIRLING BURNER OF 800MW BOILER

许昌,吕剑虹,曾庆广,郑源
DOI: https://doi.org/10.3321/j.issn:0258-8013.2004.08.040
2004-01-01
Abstract:The combustion stability of an imported 800 MW boiler in Suizhong Power Plant is controlled by its central air quantity and the vane angle of second air. The tests on air dynamical field of this burner model are proceeded by a heat thread anemoscope under various conditions, and resulting in that the ratio of central air to second air is about 5%-6%,and the vane angle of second air is about 30° - 40°,That ensures that the burning process be safe, economic and steady. How the relation caused by the adjustment of central air and second air affect the flow field is also studied. A numerical simulation on the air dynamical field of single burner is proceeded, and resulting in a coincidence with the test results, that provides a standard for design, operation and reconstruction of a high parameter and huge capacity boiler in China.
What problem does this paper attempt to address?