Scale and Rotating Velocity of a Big Shear Vortex at the Fire-facing Side of a Burner Region in a Large-sized Utility Boiler

刁永发,何伯述,许晋源,陈昌和
DOI: https://doi.org/10.3969/j.issn.1001-2060.2003.01.006
2003-01-01
Abstract:Measurements were taken of the vorticity field in the burner region of a HG-2008-YM2 type tangentially fired pulverized-coal boiler, which is considered as having a universal significance. The above measurements were conducted by employing a IFA300 constant-temperature hot wire anemometer with the use for the first time of a six-sensor hot-wire probe and its locating coordinate system. The big shear vortex at the fire-facing side of the tangentially fired burner jets is described by the use of a Rankine composite vortex. The scale and rotating velocity of the big shear vortex has been determined by a cold model test. The vortex core radius of the big shear is 25 mm, and the rotating angular velocity of an in-furnace fluid tiny bail rotating as a rigid body, -1.56 × 105 r/min. The influence of the big shear vortex on pulverized-coal ignition and the NOX nascent state in the relevant structure of the burner zone vortex was also analyzed.
What problem does this paper attempt to address?