Sol-Gel Derived Carbon Ceramic Electrode Bulk-Modified With Tris(1,10-Phenanthroline-5,6-Dione)Iron(Ii) Hexafluorophosphate And Its Use As An Amperometric Iodate Sensor

Peng Wang,Guoyi Zhu
DOI: https://doi.org/10.1002/cjoc.20020200208
IF: 5.56
2002-01-01
Chinese Journal of Chemistry
Abstract:A surface-renewable tris (1,10-phenanthroline-5, 6-dione) iron (II) hexafluorophosphate (FePD) modified carbon ceramic electrode was constructed by dispersing FePD and graphite powder in methyltrimethoxysilane (MTMOS) based gels. The FePD-modified electrode presented pH dependent voltammetric behavior, and its peak currents were diffusion-controlled in 0.1 mol/L Na2SO4 + H2SO4 solution (pH = 0. 4). In the, presence of iodate, clear electrocatalytic reduction waves were observed and thus the chemically modified electrode was used as an amperometric sensor for iodate in common salt. The linear range, sensitivity, detection limit and response time of the iodate sensor were 5 x 10(-6)-1 x 10(-2) mol/L, 7.448 muA.L/mmol, 1.2 x 10(-6) mol/L and 5 s, respectively. A distinct advantage of this sensor is its good reproducibility of surface-renewal by simple mechanical polishing.
What problem does this paper attempt to address?