Steady-state Characteristics of Synchronous Generators with AC and DC Stator Connections

王善铭,王祥珩,李义翔,苏鹏声,马伟明,张盖凡
DOI: https://doi.org/10.3321/j.issn:1000-0054.2001.09.007
2001-01-01
Abstract:In order to consider the effects of saturation of the magnetic circuit and commutation of the rectifier on the voltage harmonic distortion of the AC voltage and the variation range of the DC voltage, a mathematical model on the basis of multi loop method and finite element method (FEM) is presented for a synchronous generator with AC and DC stator connections. A connection transformation matrix is used to represent the topology relation between the generator and loads. It is aimed at accurately calculating the steady state characteristics and the waveforms of AC windings. With this method, the full synergic effects of space harmonics resulting from the magnetic circuit geometry, saliency, saturation, winding layouts, slotting are included. The calculated results are compared with those of experiments.
What problem does this paper attempt to address?