Transient Behavior of Internal Faults in Stator Windings of Salient-Pole

OUYANG Bei,Wang Xiangheng,SUN Yuguang
DOI: https://doi.org/10.3321/j.issn:1000-0054.2001.03.005
2001-01-01
Abstract:Large capacity electrical machines are expensive and complicated. Faults in such machines result in large losses. The multi-loop method was used to develop a mathematical model for salient-pole synehronous machines. The transient and steady-state behavior of the machine with internal faults was simulated using the model, with the results consistent with experimental results. The simulation program was used to study the characteristics of the transient process and the variation of the currents and voltages in a machine with internal faults.
What problem does this paper attempt to address?