Steady-state Currents Harmonic Characteristics of Synchronous Machine With Inter-turn Short Circuits of Field Windings

SUN Yuguang,HAO Liangliang,WANG Xiangheng
2010-01-01
Abstract:In order to find out the physical principles behind inter-turn short circuits of field windings in synchronous machines, theoretical analysis was performed on the interaction of stator MMF and rotor MMF in the air-gap field of a model machine named A1553 under faulty conditions, which showed that, at steady-state, the circulation current inside each phases of stator consists of fractional harmonics, while the rotor currents consists of the fundamental component and other integer harmonics. The analysis also shows that the steady-state harmonic characteristics of the field winding faults is mostly dependent on the distribution and connection pattern of stator windings, although also influenced by the pole number of the machine, short-circuit turns and position of the faults. Experiments were then carried out for inter-turn short circuits in field windings on A1553 model machine under no-load condition without network. FFT analysis of the experimental data has verified the above fault characteristics and the analytical method. Both theoretic analysis and experimental results indicate that the characteristics of inter-turn short circuits in field windings are different from other faults such as stator internal short-circuits and external short-circuits outside of synchronous machine, the results will facilitate new approaches to fault detection. © 2010 Chinese Society for Electrical Engineering.
What problem does this paper attempt to address?