Simulation Research on Inter-Turn Short Circuits of Field Windings in Synchronous Machines

Weijian Wang
2008-01-01
Abstract:When an inter-turn short circuit fault of field winding occurs in a synchronous machine,the field current will increase and the reactive power output will decrease,aggravating the rotor vibration.Severe damage will be caused to the safe operation of the machine if such faults are not handled properly in a timely manner.Existing research follows the experimental detection and qualitative analysis approaches,which are subject to practical limitations due to the fact that the fault current is not able to be calculated accurately.This paper proposes an improved multi-loop mathematical model for calculating the currents of stator and rotor as well as the active power and reactive power for the multibranch generator with inter-turn short circuit faults of field winding.Quantitatively evaluating the impact of air-gap magnetic field distortion and unbalanced current in phase windings hence becomes possible.Based on the calculation results,the paper gives a summary of the fault characteristics(e.g.,the existence of fractional harmonic circulating current and odd harmonic filed current) and their physical meanings,which may serve as the basis for the protection against inter-turn short circuit faults of field windings.
What problem does this paper attempt to address?