Detection of Micro-Cracks on Rusty Ferromagnetic Rod and Signal Analysis

于敏,胡红利,孔忻,于轮元
DOI: https://doi.org/10.3321/j.issn:0253-987X.2001.08.003
2001-01-01
Abstract:Leakage magnetic field and special differential sensor are used to detect micro-cracks on the rough surface of ferromagnetic material. The detectable depth is about 0.8-1.6 mm with a wide of about 0.5 mm. Detection is hampered if the signal is not repeated. This shortcoming can be corrected by extracting the peak signals for every crack. The corresponding wavelets are used to determine reference crack and its believable district. The technique is first developed for cracks on a smooth surface and then adjustments are made for a rough surface.
What problem does this paper attempt to address?