Abstract:Composite materials are frequently exposed to external factors during their operational service, resulting in internal structural damage which subsequently impacts their structural performance. This paper employs ferromagnetic materials for their sensitivity to magnetic field strength. By detecting variations in the magnetic field within the embedded ferromagnetic microwires of composite materials, the aim is to indirectly assess the health status of the composite materials. Firstly, a theoretical numerical model for magnetic field intensity at the crack site was established. Subsequently, a finite element model was employed to analyze the variations in the magnetic characteristics of ferromagnetic microwires at the crack site. Under different parameter conditions, the patterns of magnetic signals at the crack site were determined. The results indicate that with an increase in the angle between the external magnetic field and the crack, the fitted curve of the magnetic signal shows a linear increase. The distance between the peak and valley of the radial magnetic signal in the axial direction decreases, and the axial magnetic signal transitions from double-peak to single-peak. With the increase in crack depth, the fitted curve of the magnetic signal shows a linear increase, and the magnetic signal at the crack tip also exhibits a linear increase. An increase in crack width leads to a non-linear decrease in the fitted curve of the magnetic signal, and after reaching a certain width, the magnetic signal stabilizes. For two identical cracks at different distances, the magnetic signal exhibits a transition from a complete pattern to two complete patterns. With the increase in the external magnetic field, the magnetic signal shows a completely regular linear increase. By analyzing and calculating the variations in magnetic signals, the patterns of magnetic characteristics under the damaged state of ferromagnetic microwires were obtained. This serves as a basis for assessing whether they can continue in service and for evaluating the overall health status of composite materials.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to evaluate the health status of composite materials by detecting the magnetic field changes of ferromagnetic microwires in the damaged area after embedding ferromagnetic microwires in the composite materials. Specifically, the paper aims to use the sensitivity of ferromagnetic microwires to magnetic field intensity to indirectly evaluate the structural damage of composite materials by detecting the magnetic field changes near the ferromagnetic microwires inside the composite materials. ### Background of the Paper Composite materials are widely used in aerospace, automobile, construction and other fields. Due to their specific working environment, composite materials are often affected by external factors such as temperature, chemical corrosion and mechanical stress fatigue, resulting in microscopic damage inside the materials and gradually developing to failure. This damage will increase the stress transfer of adjacent fibers, which in turn affects the safety performance of the overall structure. Therefore, in the service process of composite materials, early detection and timely repair or replacement of damaged areas are crucial for ensuring safety. ### Research Methods The paper uses ferromagnetic microwires as sensors because ferromagnetic microwires have a unique giant magneto - impedance effect, are small in size, have excellent mechanical properties, respond quickly, and are highly sensitive to magnetic fields and stress. By establishing theoretical numerical models and finite element models, the changes in magnetic field characteristics of ferromagnetic microwires under different parameter conditions are analyzed to evaluate the health status of composite materials. ### Main Findings 1. **Trends in Changes of Magnetic Field Signals**: - As the angle between the external magnetic field and the crack increases, the fitting curve of the magnetic field signal increases linearly. - In the axial direction, the distance between the peak and the trough of the radial magnetic field signal decreases, and the axial magnetic field signal changes from a double - peak to a single - peak. - As the crack depth increases, the fitting curve of the magnetic field signal increases linearly, and the magnetic field signal at the crack tip also increases linearly. - As the crack width increases, the fitting curve of the magnetic field signal decreases non - linearly and tends to be stable after reaching a certain width. - For two identical cracks with different distances, the magnetic field signal changes from one complete pattern to two complete patterns. - As the external magnetic field increases, the magnetic field signal increases linearly in a completely regular manner. 2. **Relationship between Magnetic Field Signals and Stress**: - The magnetic field signal in the stress - concentration area is closely related to the size and position of the crack. By detecting the changes in the magnetic field signal, information on the size, position, and potential restart and expansion of the crack can be obtained. ### Conclusion By analyzing and calculating the changes in the magnetic field signals of ferromagnetic microwires in the crack area, the paper successfully predicts the damage state of ferromagnetic microwires during the service process, providing a basis for evaluating whether ferromagnetic microwires are suitable for continued use in the health monitoring of composite materials. This method provides a new non - contact detection means for the health monitoring of composite materials.