OPTIMUM PACKING FACTOR OF THE STACK MADE OF DENSE-MESH WIRE SCREENS

邱利民,蒋宁,陈国邦
DOI: https://doi.org/10.3321/j.issn:0254-0096.2001.03.017
2001-01-01
Abstract:A bench of pulse tube refrigerator driven by a standing-wave thermoacoustic prime mover was set up to study the relationship among stack, regenerator and working fluids. The stack which is the key component of thermoacoustic prime mover is packed with dense-mesh wire screens because of their low cost. The effect of packing factor in the stack on onset temperature, refrigeration temperature and input power was studied. The optimum packing factor of 1.15 pieces per millimeter was found, which provides an empirical value to make a compromise between enhancing thermoacoustic effect and decreasing heat conduction and fluid-friction loss along the stack. The pressure characteristics of the pulse tube cooler were described. The cryocooler can obtain minimum refrigeration temperature as low as 138 K and 196 K with helium and nitrogen respectively.
What problem does this paper attempt to address?