Design of High-power Density and High-frequency Transformers for Auxiliary Power Supply System in Electric Multiple Units
Yunhao Xiao,Chi Li,Xuan Guo,Yalong Liu,Zedong Zheng,Yongdong Li
DOI: https://doi.org/10.1109/tte.2024.3428861
IF: 6.519
2024-01-01
IEEE Transactions on Transportation Electrification
Abstract:The electric multiple units auxiliary power supply system has high requirements on the power density of the converter. Isolated DC/DC converter is an important part. The high frequency transformer can account for one-third of the volume of the isolated DC/DC converter, which needs optimization. Due to insulation requirements, transformers may present non-ideal geometric structures such as unequal heights of primary and secondary windings, etc., which affect the optimization accuracy of transformers and are not taken into account by traditional optimization methods. This paper considers the influence of non-ideal geometric structure on the optimization accuracy of the transformer, multiple optimization degrees of freedom such as magnetic core and winding geometric parameters, electromagnetic parameters, etc. as well as the priority of variables in the optimization design process, to achieve the faster global optimal design of the transformer. Furthermore, the power density of the transformer is further improved through a new heat dissipation structure. The optimization method proposed in this paper is applied to a 40kW/50kHz transformer, and the power density and efficiency can reach 46kW/L and 99.3%, respectively.