Abstract:This paper presents the study of design, manufacturing, calibration, and application of a (100) silicon stress testing chip for IC packages. The piezoresistive stress test chip contains optimal dual polarity four elements piezoresistive sensor rosettes and off-axis three elements piezoresistive coefficients calibration rosettes. The piezoresistive sensor rosettes offer high sensitivity to stress, and the outputs are both temperature compensated and insensitive to rotational alignment error. By using this stress test chip, the chip stress state of IC card under bending and twisting condition has been studied. The measurement results are: for upward bending along card's long edge, the in-plane normal stress difference σ 11-σ 22 is about 75 MPa, downward bending increases it by about 20%, the σ 11-σ 22 for upward bending along card's short edge is about 100 MPa, and the shear stress is small at bending condition. The in-plane shear stress σ 12 for card twisting is about 25 MPa, which is larger than normal stress.