Vibration analysis on the hot gas conduit in 10MW HTR

Hanliang Bo,Meisheng Yao,Yunxian Tong,Changwen Ma
1997-01-01
Abstract:Based on structural characteristics of the hot gas conduit for the high temperature gas cooled reactor (HTR), which inside and outside is blown by the reverse direction two flows at same time. For design condition, this paper established a theoretical model to study flow induced vibration, that is a single span cylinder contained flowing gas and surrounded by reverse direction flow, simply supported at each end; showed the mathematical equations and the simple method to solve it; and obtained the frequency as a function of flow velocity, the critical velocity at which a cylinder lost stability in various flow conditions, and the stability map. The analysis results are that the design condition of hot gas conduit falls in the stability area, in other words, running at design condition, the flow induced large amplitude vibration doesn't exist.
What problem does this paper attempt to address?