Analysis of flow instabilities for HTR-10 steam generator using frequency domain control theory

Weihua Li,RiZhu Li,Xiangwu Ding,Weimin Ying
1995-01-01
Abstract:The HTR-10 (10MW high temperature gas cooled reactor) steam generator is a once-through steam generator, and operates at a pressure of 4.0 MPa, and two phase flow instabilities must be paid attention to. This paper analyzes two phase flow density-wave instabilities using a frequency domain control theory for the HTR-10 steam generator. The mathematics expressions of heat transfer and flow of the steam generator are proposed, and the eigenfunction of the close loop system is deduced using the linear perturbation theory and Laplace transformation. System stability is judged by the Nyquist stability criterion of automatic control theory. On the above basis, the computer code ADIS is derived, and the stability analysis of the HTR-10 steam generator is made by using this code. The calculated results indicate that the two phase flow of the HTR-10 steam generator is stable.
What problem does this paper attempt to address?