Experimental study on flow break by nuclear heating reactor LOCA under shutting down incompletely

Jinhai Bo,YouJie Zhang,Shaorong Wu,Bing Han,Xuedong He
1996-01-01
Abstract:The primary circuit of 5 MW nuclear heating reactor and 200MW nuclear heating reactor are integral natural circulation systems. An experiment of the influence of flow break on the cooling core and stability of primary circuit was carried out on the thermohydraulic test system HRTL-5. The system pressure was 1.5 MPa, and the heating power under the accident was kept 20% of steady state power. The results show that the main stable drop of the pressure and the heated element temperature are not too high and couldn't be burnout. But the flow oscillation in the primary coolant circuit occurs when the flow breaks completely at the end, which is unfavorable.
What problem does this paper attempt to address?