A Novel Structure of Transmission Line Pulse Transformer with Mutually Coupled Windings

Binxiong Yu,Jiancang Su,Rui Li,Liang Zhao,Xibo Zhang,Junjie Wang
DOI: https://doi.org/10.1063/1.4867250
2014-01-01
High Power Laser and Particle Beams
Abstract:A novel structure of transmission line transformer (TLT) with mutually coupled windings is described in this paper. All transmission lines except the first stage of the transformer are wound on a common ferrite core for the TLT with this structure. A referral method was introduced to analyze the TLT with this structure, and an analytic expression of the step response was derived. It is shown that a TLT with this structure has a significantly slower droop rate than a TLT with other winding structures and the number of ferrite cores needed is largely reduced. A four-stage TLT with this structure was developed, whose input and output impedance were 4.2 Ω and 67.7 Ω, respectively. A frequency response test of the TLT was carried out. The test results showed that pulse response time of the TLT is several nanoseconds. The TLT described in this paper has the potential to be used as a rectangle pulse transformer with very fast response time.
What problem does this paper attempt to address?