SIMULATION ANALYSIS AND INDUSTRIAL VALIDATION FOR ENERGY SAVING WITH INCREASING CONCENTRATION OF EFFICIENT DESULFURIZATION SOLUTION IN REFINERY GAS DESULFURIZATION SYSTEM

Feng Zhang,Benxian Shen,Hui Sun
DOI: https://doi.org/10.3969/j.issn.1005-2399.2014.01.019
2014-01-01
Abstract:The constituent of energy consumption in the stripper for efficient desulfurization solvent (XDS) was analyzed with energy balance. Results suggested that, the energy required to heat amine solution accounted for the major part of the reboiler heat duty, and had the most significant impact on the energy consumption of the whole desulfurization system. The effect on reducing energy consumption with increasing the mass fraction of XDS solution for refinery gas desulfurization system was simulated and analyzed by the process simulation software Aspen HYSYS, and then industrial validated in a petrochemical enterprise. Simulation results showed that, the steam consumption for the stripper could be reduced by increasing mass fraction of lean solution and reducing solution circulation flow rate under the premise of ensuring the quality of purified gas. Industrial test results matched well with the simulated ones. In the petrochemical enterprise, the mass fraction of lean solution was increased from 23. 82% to 44. 40%, while the rich solution flow rate and corresponding steam consumption for the stripper could be reduced by 20. 4% and 20. 6%, respectively, which displayed the positive energy saving effect. Prior and post to increase mass fraction of lean solution, the foaming tendency and corrosive nature of XDS solution kept lower levels, and the desulfurization efficiency of the units remained stable.
What problem does this paper attempt to address?