(Invited) integration of Microneedles and Electrochemical Sensors for Medical Applications
Roger Narayan
DOI: https://doi.org/10.1149/ma2023-01341942mtgabs
2023-08-28
ECS Meeting Abstracts
Abstract:Microneedles are small-scale devices that may be used for access to interstitial fluid and/or capillary blood for transdermal monitoring of chemicals [1]. In this presentation, the integration of several types of electrochemical sensors with hollow microneedles will be considered. For example, carbon fiber electrodes have been integrated with digital micromirror device-produced microneedles; ascorbic acid and hydrogen peroxide were detected with these devices [2]. Carbon paste electrodes have also been integrated with digital micromirror device-produced microneedles; electrodes made from rhodium-dispersed carbon paste were used for hydrogen peroxide sensing [3]. In addition, lactate oxidase-modified rhodium-dispersed carbon paste electrodes were demonstrated for lactate sensing, including in the presence of interferents such as ascorbic acid, uric acid, and acetaminophen. A multiplexed microneedle array containing digital micromirror device-produced microneedles was subsequently used for amperometric detection of glucose, lactate, and pH; detection of these analytes in complex media was shown [4]. More recently, digital micromirror device-produced hollow microneedles were modified with a working sensor, which was prepared with graphene ink and 4 (3-Butyl-1-imidazolio)-1-butanesulfonate) ionic liquid. Direct oxidation of fentanyl via square-wave voltammetry was shown; a detection limit of 27.8 μM was demonstrated using this approach [5]. Two photon polymerization has also been used to create hollow microneedles for biosensing; a porous carbon electrode created using interference lithography was used for potassium ion sensing in the presence of interfering sodium ions [6]. In another study, nitrogen-incorporated ultrananocrystalline diamond coatings were deposited on Ti –6Al–4V alloy microneedles using microwave plasma enhanced chemical vapor deposition; dopamine and uric acid were electrochemically detected in an in vitro study [7]. These studies indicate that microneedles may have utility for minimally invasive detection of analytes in a real time manner. Benefits and disadvantages of the microneedle-based sensing approach as well as efforts needed for clinical translation of microneedle-based sensing technology will be considered. References [1] Miller PR, Narayan RJ, Polsky R. Microneedle-based sensors for medical diagnosis. Journal of Materials Chemistry B. 2016;4:1379-1383. [2] Miller PR, Gittard SD, Edwards TL, Lopez DM, Xiao X, Wheeler DR, Monteiro-Riviere NA, Brozik SM, Polsky R, Narayan RJ. Integrated carbon fiber electrodes within hollow polymer microneedles for transdermal electrochemical sensing. Biomicrofluidics. 2011;5:013415. [3] Windmiller JR, Zhou N, Chuang MC, Ramírez GV, Santhosh P, Miller PR, Narayan R, Wang J. Microneedle array-based carbon paste amperometric sensors and biosensors. Analyst. 2011;136:1846-1851. [4] Miller PR, Skoog SA, Edwards TL, Lopez DM, Wheeler DR, Arango DC, Xiao X, Brozik SM, Wang J, Polsky R, Narayan RJ. Multiplexed microneedle-based biosensor array for characterization of metabolic acidosis. Talanta. 2012;88:739–742. [5] Joshi P, Riley PR, Mishra R, Azizi Machekposhti S, Narayan R. Transdermal polymeric microneedle sensing platform for fentanyl detection in biofluid. Biosensors. 2022 Mar 27;12:198. [6] Miller PR, Xiao X, Brener I, Burckel DB, Narayan R, Polsky R. Microneedle-based transdermal sensor for on-chip potentiometric determination of K+. Advanced Healthcare Materials. 2014;3:876-881. [7] Skoog SA, Miller PR, Boehn RD, Sumant AV, Polsky R, Narayan RJ. Nitrogen-incorporated ultrananocrystalline diamond microneedle arrays for electrochemical biosensing. Diamond and Related Materials. 2015;54:39-46.