Interference and Error Analysis of Silicic Acid in Ion Exchange Method for Determination of SO3 in Cement

张磊,郭丽萍,杜小弟,张绪清,陈刚,雷家珩
DOI: https://doi.org/10.3963/j.issn.1671-4431.2013.12.010
2013-01-01
Wuhan Ligong Daxue Xuebao/Journal of Wuhan University of Technology
Abstract:For the error problem of ion exchange method in cement, the paper measured and contrasted the dissolved silicate of the National standard GB/T 176-2008 and GB/T 176-1976 ion-exchange process of SO3 in cement through the ICP-AES, established the quantitative relationship between silicate and error, and discussed the interference mechanism of silicate by potentiometric titration and theoretical calculation. The results show that there will dissolve more free silica by the new national standard (GB/T 176-2008) ion exchange process to extract SO3, about 15 mg (SiO2), which reduces system pH of stoichiometric point below 7.0 of acid-base titration, and the abrupt range narrow. when the phenolphthalein is to be as indicator(8.0~9.6), which is significantly higher than the stoichiometric point and the range. the silicate will participate in acid-base titration reaction, increases the titration results and uncertainty, the system error can be up to 0.65 mg(SO3), resulting in the end color change is not obvious, and increasing the uncertainty. When selecting indicator color change between the pH is 4.3~7.5, the interference of silicate can be negligible, and the SO3 determination results of error can be controlled within ± 0.1%.
What problem does this paper attempt to address?