Experimental study on precast concrete sandwich insulation shear walls under low reversed cyclic loading

Weichen Xue,Jialin Yang,Niancai Dong,Kang Li
DOI: https://doi.org/10.3969/j.issn.1001-0505.2013.05.033
2013-01-01
Abstract:Tests of five full-scale precast concrete sandwich insulation shear walls and one cast-in-place ( CIP) concrete shear wall were carried out under low reversed cyclic loading.The main pa-rameters of specimens are row number of connected vertical reinforcing bars ( single-row or double-row) , number of connected vertical reinforcing bars ( full or part ) , thickness of external concrete wythe, insulation layer and internal concrete wythe ( two kinds of cross sections of precast specimens with 200 mm+50 mm+60 mm and 100 mm+50 mm+100 mm respectively) .The results show that all specimens fail in bending.The CIP concrete and the 200 mm+50 mm+60 mm precast shear walls exhibit similar energy dissipation and displacement ductility.Comparatively, the energy dissi-pation and the displacement ductility of the 100 mm +50 mm +100 mm precast shear walls are slightly poor.In addition, the bearing capacity, displacement ductility and energy dissipation of pre-cast walls with single-row full connected vertical reinforcing bars are similar to those of the walls with double-row full connected reinforcing bars.In comparison, the former two capacities of precast walls with single-row partially connected vertical reinforcing bars are relatively higher.The energy dissipations of these three kinds of precast walls are almost the same.
What problem does this paper attempt to address?