Experimental investigation of shear resistance of cold-formed steel framed sheathed walls

Yunpeng Xu,Xuhong Zhou,Yu Shi,Yuxuan Zou,Yi Xiang,Lei Xu
DOI: https://doi.org/10.1016/j.jcsr.2020.106488
IF: 4.349
2021-03-01
Journal of Constructional Steel Research
Abstract:<p>Through an experimental investigation of the lateral resistance of seven full-scale cold-formed steel (CFS) framed sheathed walls under monotonic loading and reversed-cyclic loading, the mechanical properties, failure modes, and seismic performance of the walls are elucidated. The influence of loading mode, vertical load and sheathing material on the shear bearing capacity and hysteresis performance dissipation of the walls are analyzed. The results show that the shear bearing capacity of the single-sided 12-mm-thick gypsum panel CFS wall is about 34%—37% that of the single-sided 9-mm-thick oriented strand board panel CFS wall, and the shear bearing capacity of the double panel CFS wall is nearly equal to the sum of the two kinds of single-sided panel CFS wall. The mode of loading has a significant influence. The shear resistance of the CFS wall under monotonic loading is 5%–20% higher than that of the CFS wall under the reversed-cyclic load. The application of the vertical load improves the stiffness and the shear bearing capacity of the CFS wall, but the ductility coefficient is slightly decreased.</p>
construction & building technology,engineering, civil
What problem does this paper attempt to address?
The paper attempts to address the issue of studying the shear performance of cold-formed steel (CFS) frame sheathed walls under monotonic loading and reversed cyclic loading. Specifically, the authors experimentally investigated the mechanical properties, failure modes, and seismic performance of seven full-scale CFS walls under different loading modes, vertical loads, and sheathing materials. The main objectives of the study include: 1. **Evaluating the impact of sheathing materials**: Comparing the shear capacity of CFS walls with single-sided 12 mm thick gypsum board and CFS walls with single-sided 9 mm thick oriented strand board (OSB). 2. **Analyzing the impact of loading modes**: Exploring the effect of monotonic loading and reversed cyclic loading on the shear performance of CFS walls. 3. **Studying the role of vertical loads**: Analyzing the impact of vertical loads on the stiffness and shear capacity of CFS walls. 4. **Validating design codes**: Comparing the experimental results with the design values in the "Technical Specification for Cold-formed Thin-walled Steel Structures" (JGJ/T 421-2018) to verify the applicability of the code. Through these studies, the authors hope to provide scientific evidence for the design and application of CFS walls, particularly to promote the application of CFS structures in engineering practice in China.