Experimental Study on the Performance of a Small Inverse Brayton Air Refrigerator at -120 ℃
Zhao Hongli,Hou Yu,Chen Rugang,Chen Chunzheng
DOI: https://doi.org/10.3321/j.issn:0253-987x.2007.08.024
2007-01-01
Abstract:A multipurpose test-bed for inverse Brayton air refrigerator was rebuilt,in which the experiments were executed on the two key parts of the system,the turbo expander and the compact heat exchanger.The thermodynamic performances of efficiency,temperature drop characteristics, flow resistance,and refrigeration effect,etc.were analyzed thoroughly under design conditions,and examinations were done under overworking conditions. The test results show that the refrigeration capacity of this refrigerator is73 ℃(with the cooling load of 250 W)~-120 ℃(with the cooling load of 50 W),the maximum temperature difference between system inlet and expander outlet is 150 ℃,and the expander efficiency can reach 60.5% while the heat exchanger efficiency reaches 97.5%.The minimum temperature of the system reaches-123 ℃,which meets the requirement of heat load of 5 W at-120 ℃.Through the test and analysis,the parameters influence relation and the parameters matching relation in high speed small turbo-expanders and compact heat exchangers are obtained.