Study on the Dynamic Cooling Performance of A-150 ℃ Reverse Brayton Cycle Air Cryocooler

CAI Junwei,SUN Wan,LI Bin,LI Tao,HOU Yu
DOI: https://doi.org/10.7652/xjtuxb201303011
2013-01-01
Abstract:A turboexpander having a working wheel with a diameter of 24 mm and a plate-fin heat exchanger were applied in a retrofitted-150 ℃ air cryocooler system.A vacuum cryogenic trap(absolute pressure 10-3 Pa) was used for insulation.The dynamic cooling performance of the whole system was studied under the conditions of different brake wheel configurations.A numerical model in respect of the dynamic cooling performance of the-150 ℃ air cryocooler system was established.The results show that the brake wheel size significantly affects the cooling performance of the cryocooler,and the lowest system temperature is under-150 ℃.Additionally,the numerical results agree well with the experimental data.
What problem does this paper attempt to address?