Experimental analysis on the performance of a regenerative brayton refrigeration cycle

Hong-li ZHAO,Yu HOU,Lan XI,Xiu-fang LIU
2009-01-01
Abstract:The thermodynamic performance of a small air refrigerator and its components was experimentally studied to provide reliable and detailed data for the research on the flow and heat transfer in turbomachinery, and for the design and optimization of air refrigerator. The effects of operation structural parameters on the overall performance of the air refrigerator and its key components (turbo-expander and compact heat exchanger) were presented. Moreover, mechanical characteristics of the compliant foil bearings were examined, and over-speed test was conducted at 24.6×10.4 r/min. Results show that the turbo-expander can work stably at 22×10.4 r/min with the efficiency of 60%. The lowest temperature of -101°C is obtained at the outlet of the turbo-expander, and the temperature difference between the system inlet and the turbo-expander outlet has reached 122°C.