A Novel Initial Rotor Position Estimation Method for Permanent Magnet Synchronous Motors

Yituo LI,Haifeng LU,Wenlong QU,Shuang SHENG
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2013.03.010
2013-01-01
Abstract:When the permanent magnet synchronous (PMSM) is surface mounted and the magnetic saturation is not obvious, the inductances of dq-axes are almost the same, the traditional methods based on measuring the inductance cannot be used. In order to solve the problem, a novel initial rotor position estimation method based on rotor micro-movement is proposed. A rotating voltage vector is imposed on the stator, and the pulsating torque would be produced due to the generated rotating current vector. Rotor micro-movement would emerge with appropriate pulsating torque, and it will affect the current response. As the pulsating torque is concerned with the rotor position, the rotor position information would be contained in the current response. According to the model of the motor, the current responses under voltage vector with different frequencies are analyzed in this paper. Fourier analysis is used to calculate the current response, and the rotor position is obtained. Experiments are done on a built 1.25 kW PMSM platform, and the effectiveness of the proposed method is verified. © 2013 Chinese Society for Electrical Engineering.
What problem does this paper attempt to address?