Abstract:A method was preserted to detect the initial rotor position using oscillating voltage injection for permanent magnet synchronous motors.The Taylor series was used to describe the characteristic of nonlinear magnetic saturation relationship between the current and the flux linkage in rotor reference frame.And through the analysis of high-frequency current response,the fundamental component of the q-axis current includes the rotor position information but it has multiple solutions,while the second harmonic component of d-axis current contains the polarity information and it can effectively filter out invalid solutions.Then a PI controller was designed shich can quickly make estimate frame approaching the rotor reference frame.The fundamental component of q-axis current tends to zero when the second harmonic component of d-axis current tends to the minimum value.So the true value of the rotor initial position were obtained.Finally,the result of simulation demonstrates the effectiveness of this method.