Magnetostrictive/piezoelectric Drum Magnetoelectric Transducer for H2 Detection

Yanmin Jia,A'Xi Xue,Zhihua Zhou,Zheng Wu,Jianrong Chen,Ke Ma,Yihe Zhang,Jiayi Zhou,Yu Wang,Helen Lai Wa Chan
DOI: https://doi.org/10.1016/j.ijhydene.2013.09.035
IF: 7.2
2013-01-01
International Journal of Hydrogen Energy
Abstract:A magnetostrictive/piezoelectric drum magnetoelectric transducer has been fabricated for H-2 detection. Due to the difference in the acoustic wave velocity for H-2 (1284 m/s) and air (331 m/s), the resonance frequency of the magnetoelectric coupling effect will shift when H-2 gas enters the drum cavity filled with air. A good linear relationship between the resonance frequency shift (Delta f) and the volume fraction of H-2 (n%) is observed. The resolution on the H-2 volume fraction of our magnetoelectric drum detector was experimentally observed as similar to 0.25%. The detection coefficient (Delta f/n) for H-2 volume fraction of our ME drum transducer is approximately equal to similar to 0.48 kHz. The magnetoelectric drum is hopeful for H-2 physical detection. Copyright (C) 2013, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?