Research on Insulation Coordination for Converter Stations of Zhoushan Multi-Terminal VSC-HVDC Transmission Project

周浩,沈扬,李敏,田杰,邓旭,陈锡磊,周志超,王东举
2013-01-01
Abstract:The insulation coordination for converter station is one of the key technologies to implement flexible DC power transmission projects, and the results of the research on this field can provide important guidance to the design, type selection, manufacture and test of converter equipments in converter stations. To decide insulation levels for equipments of converter stations in Zhoushan multi-terminal flexible DC power transmission project reasonably, the arrester layout schemes for converter stations are proposed; corresponding arrester parameters and protection levels are calculated; the recommended insulation margins for equipments in converter stations are given and based on the selected equipment insulation margins the insulation levels for equipments in converter stations are finally determined. Insulation coordination results corresponding to three different arrester layout schemes are given and the coordination results show that different arrester layout schemes mainly influence on the insulation levels among terminals of reactors connected to bridge arms:for the first arrester layout scheme, the insulation levels of lightning impulse and that of switching impulse among reactor terminals connected to bridge arms are 450 kV and 325 kV respectively, and for the second and the third arrester layout schemes the insulation levels among reactor terminals connected to bridge arms are the same and the insulation level of lightning impulse and that of switching impulse are 750 kV and 550 kV respectively. Except reactors connected to bridge arms, the recommended insulation levels for other equipments in converter stations under all arrester layout schemes are the same;for AC equipments at valve side of converter transformer the insulation levels of lightning impulse are recommended as 650 kV (or 750 kV) and the insulation level of switching impulse is recommended as 550 kV; the insulation level of lightning impulse and that of switching impulse for AC equipments at valve side of bridge arm reactors are taken the same as these for equipments at valve side of converter transformer; the insulation levels of lightning impulse of 200 kV DC buses in converter stations are recommended as 650 kV (or 750 kV) and that of switching impulse is recommended as 550 kV; the insulation levels of lightning impulse and these of switching impulse among terminals of DC smoothing reactors are taken as 850 kV (or 950 kV) and 750 kV respectively. Besides, the advantages and disadvantages of the three arrester layout schemes are analyzed. Results of this research topic can offer important foundation for Zhoushan multi-terminal flexible DC power transmission project and are available for reference to other VSC-HVDC projects.
What problem does this paper attempt to address?