FEA-based calculation of leakage inductance for high-voltage high-power E-core transformer

Yachao Wang,Jun Liu,Xiangning He
DOI: https://doi.org/10.3969/j.issn.1006-6047.2013.02.019
2013-01-01
Abstract:A two-dimensional ERXP model is built for the gapless E-core transformer with rectangular interior column. Its ER model is built on the section perpendicular to the longest edge of magnetic core and its XP model on the section parallel to the longest edge. The rectangular section is then equivalent to a circular section with same area. The dimensions of ER or XR model are calculated while keep the magnetic resistance of its interior column equal to that of the actual transformer. The three dimensional magnetic field of actual transformer is equivalent to the weighted average of the simulated results of two models, based on which, the leakage inductance is figured out. Simulative results show that the energy of the leakage inductance is mainly concentrated between the primary and the secondary windings, consistent with the theoretical analysis. The leakage inductance calculated with the ERXP model is 7.25 μH, 4.6% lower than the measured leakage inductance(7.6 μH), better than the one dimensional analysis.
What problem does this paper attempt to address?