Simulation and Optimization of Natural Gas Desulfurization Device

WANG Jin,LI Zhen,FAN Zheng,LI Wen-hong,LIU Yan-jun
DOI: https://doi.org/10.3969/j.issn.1005-9954.2013.01.018
2013-01-01
Abstract:Aiming at the serious reality of excessive CO2 volume fraction and the resulting frequent malfunction in production equipment and pipelines in a natural gas purification plant of Shanbei,the whole desulfurization system was simulated and optimized by using ChemCAD 6.0.1 professional software.Some key equipment was checked with FRI-Tray Rating 1.0.7,HTRI Xchanger Suit 4.00 and other professional software.The results show that the quality of gas product can achieve international relevant requirements by increasing methyldiethanolamine(MDEA) circulation quantities properly.The hydrodynamic parameters in MDEA absorption tower all meet the requirements of new technical conditions.Adding a same one in series can remedy the low heat load of the rich and poor fluid heat exchanger.The increase of surface fin ratio of acid gas air cooler can satisfy the heat exchange requirements.The replacement of the original recycle pump with the high-power pump can make sure that MDEA circulation quantities meet the specified requirements of the system.