Application of Regent Mechanical Valve in Patients with Small Aortic Annulus: 3-Year Follow-Up.

Dong Zhao,Chunsheng Wang,Tao Hong,Cuizhen Pan,Changfa Guo
DOI: https://doi.org/10.1186/1749-8090-7-88
2012-01-01
Journal of Cardiothoracic Surgery
Abstract:Background Aortic valve replacement (AVR) with a small aortic annulus is always challenging for the cardiac surgeon. In this study, we sought to evaluate the midterm performance of implantation with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve in retrospective consecutive cohort of patients with small aortic annulus (diameter ≤ 19 mm). Methods From January 2008 to April 2011, 40 patients (31 female, mean age = 47.2 ± 5.8 years) with small aortic annulus (≤19 mm in diameter) underwent aortic valve replacement with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve. Preoperative mean body surface area, New York Heart Association class, and mean aortic annulus were 1.61 ± 0.26 m 2 , 3.2 ± 0.4, and 18 ± 1.4 mm respectively. Patients were divided into two groups, according to the implantation of 17 mm SJM Regent mechanical valve (group 1, n = 18) or 19 mm SJM Regent valve (group 2, n = 22). All patients underwent echocardiography examination preoperatively and at one year post-operation. Results There were no early deaths in either group. Follow-up time averaged 36 ± 17.6 months. The mean postoperative New York Heart Association class was 1.3 ± 0.6 (p < 0.001). By echocardiography, in group 1, the left ventricular ejection fraction (LVEF), left ventricular fraction shortening (LVFS), and the indexed effective orifice area (EOAI) increased from 43.7% ± 11.6%, 27.3% ± 7.6%, and 0.70 ± 0.06 cm 2 /m 2 to 69.8 ± 9.3%, 41.4 ± 8.3%, and 0.92 ± 0.10 cm 2 /m 2 respectively ( P < 0.05), while the left ventricular mass index (LVMI), and the aortic transvalvular pressure gradient decreased from 116.4 ± 25.4 g/m 2 , 46.1 ± 8.5 mmHg to 86.7 ± 18.2 g/m 2 , 13.7 ± 5.2 mmHg respectively. In group 2, the LVEF, LVFS and EOAI increased from 45.9% ± 9.7%, 30.7% ± 8.0%, and 0.81 ± 0.09 cm 2 /m 2 to 77.4% ± 9.7%, 44.5% ± 9.6%, and 1.27 ± 0.11 cm 2 /m 2 respectively, while the LVMI, and the aortic transvalvular pressure gradient decreased from 118.3 ± 27.6 g/m 2 , 44.0 ± 6.7 mmHg to 80.1 ± 19.7 g/m 2 , 10.8 ± 4.1 mmHg as well. The prevalence of PPM was documented in 2 patients in Group 1. Conclusions Patients with small aortic annulus and body surface area, experienced satisfactory clinical improvement after aortic valve replacement with modern SJM Regent bileaflet prostheses.
What problem does this paper attempt to address?