A centrifuge simulated push–pull manoeuvre with subsequent reduced +Gz tolerance

Yan Xu,Bao-Hui Li,Li-Hui Zhang,Zhao Jin,Xiao-Yang Wei,Hong Wang,San-Yuan Wu,Hai-Xia Wang,Quan Wang,Gui-Ding Yan,Lue Deng,Xi-Chen Geng
DOI: https://doi.org/10.1007/s00421-011-2234-3
IF: 3.346
2011-01-01
European Journal of Applied Physiology
Abstract:The push–pull effect (PPE) has been recognized as a deleterious contributor to fatal flight accidents. The purpose of the study was to establish a push–pull manoeuvre (PPM) simulation with a tri-axes centrifuge, studying the effect of this PPM on the +Gz tolerance, and to make this simulation suitable for pilot centrifuge training. The PPM was realized through pre-programmed acceleration profiles consisting of −1 Gz for 5 s followed by a +Gz plateau for 10 s. Relaxed +Gz tolerance recordings were obtained from 20 healthy male fighter aircraft pilots and 6 healthy male volunteers through exposure to pre-programmed profiles with and without previous −1 Gz exposure. A statistically significant decrease in +Gz tolerance was seen in all subjects after −1 Gz for 5 s exposure, 0.87 ± 0.13 G in the volunteer group and 0.95 ± 0.25 G in the pilot group. The ear opacity pulse as a +Gz tolerance endpoint criterion was sometimes found to be unreliable during the PPM experiments. The simulated PPM in this study elicited a PPE, which was obvious from the significant reduction in +Gz tolerance. The PPM profile appears useful to be included in centrifuge training.
What problem does this paper attempt to address?