Critical Current Degradation Behavior of 7-Filamentary Ba1−x K X Fe2As2 Tapes under Uniaxial Strain
Xiao Liu,Yi Shi,Fang Liu,Hongjun Ma,Huajun Liu,Chao Zhou,Yuntao Song,Jian Gao,Yanchang Zhu,Xianping Zhang,Dongliang Wang,Yanwei Ma,Zhan Zhang,Shaoqing Wei,Jinggang Qin
DOI: https://doi.org/10.1088/1361-6668/aca4a7
2022-01-01
Superconductor Science and Technology
Abstract:122-type iron-based superconductors (IBS) have attracted extensive attention due to their excellent performance. The 100 m class Ba1−x K x Fe2As2 (Ba-122) 7-filamentary IBS tapes were successfully fabricated by the Institute of Electrical Engineering, Chinese Academy of Sciences. In this study, we have performed tests of the 7-filamentary Ba-122 short tape samples (Bas samples) and the 100 m class 7-filamentary Ba-122 tape samples (Ba100 samples) under various kinds of strain using U-shaped bending spring devices. Both types of samples were still reversible even when the applied compressive strain reached −0.65%. In addition, the reversible tensile strain limit of the Bas and Ba100 samples were 0.25% and 0.28%, which increased to 0.38% and 0.41% after considering the effect of the cooling process.