Experimental Study of Ammonia Slip of Diesel Engine Urea Selective Catalytic Reduction System in Transient Condition

ZHAO Yan-guang,HU Jing,HUA Lun,SHUAI Shi-jin,WANG Jian-xin
DOI: https://doi.org/10.3969/j.issn.1000-0925.2012.03.005
2012-01-01
Abstract:The relation between ammonia slip and ammonia storage quantity of urea selective catalytic reduction(SCR) system in transient condition was studied in engine test bench.The ammonia slip was measured in quick heating up processes of the SCR catalyst from 200℃,240℃,270℃ and 320℃ to 400℃ respectively.The effect of ammonia storage saturation level on catalyst surface on ammonia slip in transient condition was analyzed,and based on it the urea injection strategy was modified.Experimental results show that heating temperature increment results in different ammonia slips.The lower the initial temperature,the greater the ammonia slip.The ammonia storage saturation level has significant effect on the ammonia slip in transient condition.In the experiment,when the saturation level is lower than 58% of the storage capacity,the ammonia slip is nearly zero.The ESC test shows that the revised urea injection strategy makes the ammonia volumetric concentration in outlet of the SCR system lower than 10×10-6 in the whole test process without obvious decrease of NOx conversion efficiency.
What problem does this paper attempt to address?