VOC emissions from a LIFE reference: Small chamber tests and factorial studies

Wenjuan Wei,Sylvester Greer,Cynthia Howard-Reed,Andrew K. Persily,Yinping Zhang
DOI: https://doi.org/10.1016/j.buildenv.2012.05.008
IF: 7.093
2012-01-01
Building and Environment
Abstract:A liquid-inner tube diffusion-film-emission (LIFE) reference was developed to quickly evaluate the performance of a chamber system for furniture/building material VOC emission tests. The reference has a constant emission rate determined by an analytical balance at typical temperature and relative humidity conditions, and is able to provide predictable concentrations in a chamber testing system. A 51 L stainless steel chamber was used to test the LIFE reference's performance at an air temperature of 23 °C with 50% RH. Factorial studies of the LIFE reference's emission under various temperatures (10 °C, 23 °C and 30 °C) and relative humidities (33%, 50% and 70%) showed that the emission rate is sensitive to the chamber environment. A numerical regression equation was developed to describe the impact of chamber temperature, relative humidity and their interaction on the reference's emission, with the difference between prediction and testing results of less than 6% at 23 °C and 30 °C.
What problem does this paper attempt to address?