Investigation on Start-up Characteristic for Evaporator in a Capillary Loop with Phase Change

Bing Zhou,Zhengkai Tu,Zhichun Liu,Wei Liu
DOI: https://doi.org/10.3963/j.issn.1006-2823.2012.02.007
2012-01-01
Abstract:The start-up criterion of the capillary loop system with phase change was obtained by analyzing the force equilibrium of the capillary liquid column, and a three-dimensional thermal conducting model of the evaporator is established to investigate the start-up characteristics of the system. The results show that the preheating time of the evaporator decreases with increasing of the heat flux; reducing the height of the liquid compensation chamber can speed up the startup process of the evaporator and the effect would be more significant under a lower startup heat flux; besides, the preheating time can be shortened by reducing the width of the steam channels under lower startup heat flux, while the effects are not significant under high heat flux.